GeoStructures: Colombo pierCase study: SOFO SystemPier monitoring Beams deformation
Project DescriptionSummary: Installation of 24 SOFO sensors on the main beams of the pier Clients: Genoa Harbor Authority Place: Genoa (Italy) Period: 2003 - N/A Installation: Tecniter srl Structure's short description: The structure is a pier in Genoa harbor for the docking of large ships. The main structural deck consists of five U-shaped pre-fabricated beams Aim of monitoring: Thanks to the measurements obtained with the SOFO system, it'll be possible to follow the behaviour of the structure when boats dock at the pier Number of sensor: 24 Main Results: N/A
Bibliography:
Monitoring of harbor piers with fiber optic displacement sensors, D. Inaudi, G. Brunetti, A. Del Grosso, M. Fedolino, SPIE, 7th International Symposium on Smart Structures and Materials, Newport Beach, USA, Vol 3995, p 175-179, 2000 Long-term deformation monitoring of historical constructions with fiber optic sensors , D. Inaudi, N. Casanova, B. Glisic, 3rd International Seminar on Structural Analysis of Historical Constructions, Guimaraes, Portugal, November, Univrsity of Minho Publisher, pp. 421-430, 2001 Monitoring of Bridges and Concrete Structures with Fibre Optic Sensors in Europe , A. Del Grosso, K. Bergmeister, D. Inaudi, U. Santa, IABSE Conference, Seoul, Korea, August 2001, 2001 Structural Health Monitoring of Harbour Piers , A. Del Grosso, Lanata, G. Brunetti, A. Pieracci, The 3rd International Conference on Structural Health Monitoring of Intelligent Infrastructure - SHMII-3, November 13-16, On Proceedings CD, 2007
|
|
|||||||||||||||||||
|
|
||||||||||||||||||||
|
© SMARTEC SA 2009 - CREDITS |
||||||||||||||||||||