Laboratory Testing: Shaking table testCase study: SOFO SystemDynamic strain monitoring
Project DescriptionSummary: Modal analysis and damage detection on a metallic frame subject to earthquake simulation Clients: University of Pavia Place: University of Pavia (Italy) Period: 2003 - 2004 Installation: SMARTEC Structure's short description: Metallic frame Aim of monitoring: Use of the SOFO Dynamic system to acquire modal parameter and detect strain introduced to the frame culumns Number of sensor: 4 Main Results: The change in dynamic strai allowed the detection of very small damages that did not create any variation of the dynamic response and were tehrefore not identified by accellerometers
Deatil of the tested frame Bibliography:
Long-Gauge Fiber-Optic Sensors: a new Approach to Dynamic System Identification , F. Casciati, Marco Domaneschi, Daniele Inaudi, Angelo Figini, Branko Glisic, Akhilesh Gupta, Third European Conference on Structural Control, 3ECSC, 12-15 July , Vienna University of Technology, Vienna, Austria, 2004 Local damage detection from dynamic SOFO experimental data , S. Casciati, M. Domaneschi, D. Inaudi, 2005 SPIE Smart Structures Conference, San Diego, CA. March 7-10, 2005
|
|
|||||||||||||||||||
|
|
||||||||||||||||||||
|